Netscaler Upgrade

Netscaler Upgrade

NetScaler Hardware and Software Compatibility Matrix CTX113357

Backup:

  1. /var/ns_sys_backup/  (Pfad)
    create system backup -level full
    restore system backup backup_full_<nsip_address>_<date-timestamp>.tgz
/nsconfig/monitors/*.pl /nsconfig/htmlinjection/* /nsconfig/ns.conf /nsconfig/ZebOS.conf /nsconfig/rc.netscaler /nsconfig/snmpd.conf /nsconfig/nsbefore.sh /nsconfig/nsafter.sh /nsconfig/inetd.conf /nsconfig/ntp.conf /nsconfig/syslog.conf /nsconfig/newsyslog.conf /nsconfig/crontab /nsconfig/host.conf /nsconfig/hosts /nsconfig/ttys /nsconfig/sshd_config /nsconfig/httpd.conf /nsconfig/monitrc /nsconfig/rc.conf /nsconfig/ssh_config /nsconfig/localtime /nsconfig/issue /nsconfig/issue.net /nsconfig/ssl/* /nsconfig/license/* /nsconfig/fips/*

/var/custom/*
/var/download/*
/var/log/wicmd.log
/var/wi/tomcat/webapps/*
/var/wi/tomcat/logs/*
/var/wi/tomcat/conf/catalina/localhost/*
/var/nslw.bin/etc/krb.conf
/var/nslw.bin/etc/krb.keytab
/var/netscaler/locdb/*
/var/lib/likewise/db/*
/var/vpn/bookmark/*
/var/netscaler/crl
/var/nstemplates/*
/var/learnt_data/*

Upgrade:

mkdir x_xnsinstall
cd /var/nsinstall/ns-<build>
tar zxvf ns-<build>.tgz
./installns

HA Konfiguration:

set ha node -hasync disabled
cd /var/nsinstall/ns-<build> 
tar zxvf ns-<build>.tgz 
./installns
force failover

set ha node -hasync enabled

hohe und konstante CPU Nutzung 50% ab ESXi Version 6.0

set ns vpxparam -cpuyield YES

With version NetScaler 11.1, VPX was sharing CPU with other VMs. With NetScaler 12.0 version, VPX will not share CPU by default.

Links:
How to Upgrade the Software of the NetScaler Appliances in a High Availability Setup  CTX127455

Schreibe einen Kommentar